Use of a Locked Fibular Plate for Fixation of a Vertical Shear Medial Malleolus Fracture: A Case Report
Document Type
Article
Publication Title
Journal of Foot and Ankle Surgery
Abstract
Vertical shear fractures of the medial malleolus are less common than transverse fractures. These fractures are often treated with lag screws, posteromedial buttress plating, antiglide plates, and neutralization plates with screws. We report on a 37-year-old male who had fractured his ankle after tripping and falling into a ditch. Initially, the patient was treated with closed reduction and a splint for a trimalleolar fracture with a laterally subluxed talus. However, on review of his preoperative radiographs and computed tomography studies, we confirmed a medial malleolus fracture with a vertical shear pattern and communition. Recently, a contoured fibular locking plate has been developed. We considered this plate to be effective for containing the bone in part because of its broader plate design. We present a case in which a fibular locking plate was used successfully as a neutralization plate as an alternative fixation method for a vertical shear medial malleolar fracture.
DOI
10.1053/j.jfas.2015.06.016
Publication Date
11-2015
Keywords
fibular locking plate, fracture fixation, malleolar fracture, orthopedic fixation devices, tibia
ISSN
1542-2224
Recommended Citation
Blake S, Yakubek G, Shaer J. Use of a Locked Fibular Plate for Fixation of a Vertical Shear Medial Malleolus Fracture: A Case Report. Journal of Foot and Ankle Surgery. 2015; 54(6). doi: 10.1053/j.jfas.2015.06.016.